  • Chlamydia Rapid Test Kit simple operation test kit

    Chlamydia Rapid Test Kit simple operation test kit

    Sensitivity The Chlamydia Rapid Test Device has been evaluated with Chlamydia infected cells and specimens obtained from patients of STD clinics. The Chlamydia Rapid Test Device can detect 107 org/ml. Specificity The Chlamydia Rapid Test Device uses an antibody that is highly specific for Chlamydia antigen in specimens. The results show the Chlamydia Rapid Test Device has a high specificity relative to Other Test For Female Cervical Swab Specimens: Method Other Test Total             ...
  • High accuracy Infectious Disease Typhoid Test kit

    High accuracy Infectious Disease Typhoid Test kit

    Clinical Performance For IgM Test A total of 334 samples from susceptible subjects were tested by the Typhoid Antibody Rapid Test and by a commercial S. typhi IgM EIA. Comparison for all subjects is showed in the following table. Method IgM EIA Total Results  Typhoid Antibody Rapid Test Results Positive Negative Positive 31 2 33 Negative 3 298 301 Total Results 34 300 334 Relative Sensitivity:91.2% (76.3% – 98.1%)* Relative Specificity: 99.3...
  • Test Diagnostic Medical Device CE marked Syphilis Test kit

    Test Diagnostic Medical Device CE marked Syphilis Test kit

    POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T). *NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of TP antibodies present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive. NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line reg...
  • CE approved wholesale Medical Device Strep A Test kit

    CE approved wholesale Medical Device Strep A Test kit

    Accuracy Table: Strep A AntigenRapid Test vs. PCR Test Method Culture Total Results Strep A Antigen Rapid Test Results Positive Negative Positive 102 7 109 Negative 6 377 383 Total Results 108 384 492 Relative Sensitivity: 94.4% (88.3%-97.9%)* Relative Specificity: 98.2% (96.3%-99.3%)* Accuracy: 97.4% (95.5%-98.6%)* * 95% Confidence Intervals INTENDED USE The Strep A Antigen Rapid Test is a rapid chromatographic immunoassay for the qualita...
  • One step High accuracy CE approved Malaria Pf/Pan Test kit

    One step High accuracy CE approved Malaria Pf/Pan Test kit

    Sensitivity The Malaria Pf/ Pan Rapid Test Device (Whole Blood) has been tested with thin or thick microscopy on clinical samples. The results show that the sensitivity of the Malaria P.f/ Pan Rapid Test Device (Whole Blood) is >99.9% relative to microscopy. For Pan: Relative Sensitivity: >99.9% (103/103) (96.5%~100.0%)* For P.f: Relative Sensitivity: >99.9% (53/53) (93.3%~100.0%)* Specificity The Malaria Pf/ Pan Rapid Test Device (Whole Blood) uses highly specific antibodies for M...
  • One step high accuracy Malaria P.f./P.v. Test kit

    One step high accuracy Malaria P.f./P.v. Test kit

    Sensitivity The Malaria P.f./ P.v. Rapid Test Device (Whole Blood) has been tested with microscopy on clinical samples. The results show that the sensitivity of the Malaria P.f./ P.v. Rapid Test Device (Whole Blood) is >98% when compared to results obtained with microscopy. Specificity The Malaria P.f./ P.v. Rapid Test Device (Whole Blood) uses antibodies that are highly specific to Malaria P.f.-specific and P.vivax LDH antigens in whole blood. The results show that the specificity of the ...
  • Medical use professional Typhoid Test kit, one step rapid test cassette

    Medical use professional Typhoid Test kit, one step rapid test cassette

    Clinical Sensitivity, Specificity and Accuracy The Influenza A+B Antigen Rapid Test has been tested compared with RT-PCR. 539 nasopharyngeal swabs and oropharyngeal swabs were evaluated with the Influenza A+B Rapid Test. Substances Concentration Substances Concentration Nasal Spray 15% v/v Hemoglobin 10% v/v Mucin 0.5 % w/v Mupirocin 10 mg/mL Nasal Drops 15% v/v Mouthwash / Chloraseptic 1.5 mg/mL Levofloxacin 40 ug/mL  Oseltamivir 2ug/mL...
  • CE approved H. Pylori Ag Rapid Test kit, test Cassette

    CE approved H. Pylori Ag Rapid Test kit, test Cassette

    PERFORMANCE CHARACTERISTICS Table: H. Pylori Ag Rapid Test vs. Biopsy/Histology/RUT Relative Sensitivity: >95.0% (90.0%-97.9%)* Relative Specificity: >95.7% (92.3%-97.9%)* Overall Agreement: >95.4% (92.8%-97.3%)* *95% Confidence Interval H. Pylori Ag Rapid Test + - Total Biopsy/ Histology/ RUT + 131 7 138 - 10 225 235 141 232 373 INTENDED USE The H. Pylori Ag Rapid Test Device (Feces) is a rapid chromatographic immunoassay for the qualitative detection of antigens to...
  • Manufacturer Supply quality H. Pylori Ab Rapid Test kit

    Manufacturer Supply quality H. Pylori Ab Rapid Test kit

    PERFORMANCE CHARACTERISTICS Table: H. pylori Rapid Test vs. Biopsy/Histology/RUT Relative Sensitivity: >95.0% (90.0%-97.9%)* Relative Specificity: >95.7% (92.3%-97.9%)* Overall Agreement: >95.4% (92.8%-97.3%)* *95% Confidence Interval H.Pylori Rapid Test + - Total Biopsy/ Histology/ RUT + 131 7 138 - 10 225 235 141 232 373 INTENDED USE The H.Pylori Ab Rapid Test Device (Whole Blood/Serum/ Plasma) is a rapid chromatographic immunoassa...
  • Medical Diagnostic Dengue NS1 Test kit , rapid test

    Medical Diagnostic Dengue NS1 Test kit , rapid test

    ASSAY PROCEDURE Step 1: Bring the specimen and test components to room temperature if refrigerated or frozen. Mix the specimen well prior to assay once thawed. Step 2: When ready to test, open the pouch at the notch and remove device. Place the test device on a clean, flat surface. Step 3: Be sure to label the device with specimen’s ID number. Step 4: For whole blood sample: Fill the dropper with the specimen then add 2 drops(App.50µL)of specimen into the sample well. Making sure that there...