Home
About Us
Our Branch
Products
Human Test
Drug Test
Infectious Disease Test
Fertility Test
Blood Glucose Meter
Animal Test
Medical Dry Film
Blue Image Dry Film
News
FAQs
Contact Us
English
Products
Home
Products
FIV Ab/FeLV Ag/Heartworm Ag Combo Rapid Test Kits (FIV-FeLV-HW)
TEST PROCEDURE - Allow all materials, including specimen and test device, recover to 15-25℃ before running the assay. - Take out the test device from the foil pouch and place it horizontally. – Using the capillary dropper to place 10μL of the prepared specimen into the sample hole “S” of the test device. Then drop 3 drops (approx. 90μL) of the assay buffer into the sample hole immediately. - Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid. INTENDE...
inquiry
detail
Feline Herpesvirus Type-1/Calicivirus Antigen Combo Rapid Test Kits
TEST PROCEDURE Allow all materials, including specimen and test device, recover to 15-25℃ before running the assay. - Collect cat’s ocular, nasal or anus secretions with the cotton swab and make the swab wet sufficiently. - Insert the swab into the provided assay buffer tube. Agitates it to get efficient sample extraction. - Take out the test device from the foil pouch and place it horizontally. – Suck the treated sample extraction from the assay buffer tube and place 3 drops into the s...
inquiry
detail
Canine Distemper Virus Antigen Rapid Test kits (CDV Ag)
TEST PROCEDURE - Collect dog’s ocular, nasal or anus secretions with the cotton swab and make the swab wet sufficiently. - Insert the swab into the provided assay buffer tube. Agitates it to get efficient sample extraction. - Take out the test device from the foil pouch and place it horizontally. – Suck the treated sample extraction from the assay buffer tube and place 3 drops into the sample hole “S” of the test device. - Interpret the result in 5-10 minutes. Result after 10 minutes is...
inquiry
detail
Canine CDV-CAV-CIV Ag Combo Rapid Test Kits
TEST PROCEDURE - Collect dog’s ocular, nasal or anus secretions with the cotton swab and make the swab wet sufficiently. - Insert the swab into the provided assay buffer tube. Agitates it to get efficient sample extraction. – Take out the test device from the foil pouch and place it horizontally. - Suck the treated sample extraction from the assay buffer tube and place 3 drops into each sample hole “S” of the test device. - Interpret the result in 5-10 minutes. Result after 10 minutes i...
inquiry
detail
Feline Immunodeficiency Virus Antibody Rapid Test Kits (FIV Ab)
TEST PROCEDURE - Allow all materials, including specimen and test device, recover to 15-25℃ before running the assay. - Take out the test device from the foil pouch and place it horizontally. – Using the capillary dropper to place 10μL of the prepared specimen into the sample hole “S” of the test device. Then drop 2 drops (approx. 80μL) of the assay buffer into the sample hole immediately. - Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid. INTENDED...
inquiry
detail
CE Marked Urine Drug Test COT TEST KIT
A. Sensitivity One Step Cotinine Test has set the screen cut-off for positive specimens at 100 ng/mL for cotinine as the calibrators. The test device has been proved to detect above the cut-off level of the target drugs in urine at 5 minutes. B. Specificity and cross reactivity To test the specificity of the test, the test device was used to test cotinine and other components of the same class that are likely to be present in urine, All the components were added to drug-free normal human urin...
inquiry
detail
Ehrlichia – Anaplasma Antibody Combo Test Kits (EHR-ANA)
TEST PROCEDURE - Allow all materials, including specimen and test device, recover to 15-25℃ before running the assay. - Take out the test card from the foil pouch and place it horizontally. – Collect 20μL of the prepared specimen into a vial of assay buffer and mix well. Then drop 3 drops (approx. 120μL) of the diluted sample into the sample hole “S” of the test card. - Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid. INTENDED USE The Canine EHR-A...
inquiry
detail
HOT Sale Product BZO TEST KIT, Multi-Drug Test
A. Sensitivity One Step Benzodiazepines Test has set the screen cut-off for positive specimens at 300 ng/mL for oxazepam as a calibrator. The test device has been proved to detect above 300 ng/mL of Benzodiazepines in urine at 5 minutes. B. Specificity and cross reactivity To test the specificity of the test, the test device was used to test benzodiazepines, drug metabolites and other components of the same class that are likely to be present in urine, All the components were added to drug-fr...
inquiry
detail
One Step Wholesale Drug Test BUP TEST KIT
A. Sensitivity One Step Buprenorphine Test has set the screen cut-off for positive specimens at10 ng/mL for Buprenorphine as a calibrator. The test device has been proved to detect above 10 ng/ml of Buprenorphine in urine at 5 minutes. B. Specificity and cross reactivity To test the specificity of the test, the test device was used to test Buprenorphine, its metabolites and other components of the same class that are likely to be present in urine, All the components were added to drug-free no...
inquiry
detail
Customized Rapid Drug Test BAR TEST KIT
A. Sensitivity One Step Barbiturates Test has set the screen cut-off for positive specimens at 300 ng/mL for secobarbital as a calibrator. The test device has been proved to detect above 300 ng/mL of Barbiturates in urine at 5 minutes. B. Specificity and cross reactivity To test the specificity of the test, the test device was used to test barbiturates, metabolites and other components of the same class that are likely to be present in urine, All the components were added to drug-free normal ...
inquiry
detail
High sensitivity, easy and accurate HCG Test Strip (Urine)
SENSITIVITY AND SPECIFICITY The hCG One Step Pregnancy Test Strip (Urine) detects hCG at a concentration of 25mIU/mL or greater. The test has been standardized to the W.H.O. International Standard. The addition of LH (500mIU/mL), FSH (1,000mIU/mL), and TSH (1,000µIU/mL) to negative (0mIU/mL hCG) and positive (25mIU/mL hCG) specimens showed no cross-reactivity. Interfering Substances The following potentially interfering substances were added to hCG negative and positive specimens. Acetamin...
inquiry
detail
Women Home Testing Urine LH Ovulation Test Strip
LH Test PERFORMANCE CHARACTERISTICS Laboratory studies show that the sensitivity of the LH One Step Ovulation Test is 40mIU/mL and the accuracy is 99.1%. DIRCTIONS FOR USE Allow the test, urine specimen and/or controls to reach room temperature (15-30°C) prior to testing. Determine the day to begin testing. (See the above section: “WHEN TO START TESTING”) Strip: 1.Bring the pouch to room temperature before opening it. Remove the test strip from the sealed pouch and use it as soon as possible....
inquiry
detail
<<
< Previous
1
2
3
4
5
6
Next >
>>
Page 3 / 6
Hit enter to search or ESC to close
English
French
German
Portuguese
Spanish
Russian
Japanese
Korean
Arabic
Irish
Greek
Turkish
Italian
Danish
Romanian
Indonesian
Czech
Afrikaans
Swedish
Polish
Basque
Catalan
Esperanto
Hindi
Lao
Albanian
Amharic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Bulgarian
Cebuano
Chichewa
Corsican
Croatian
Dutch
Estonian
Filipino
Finnish
Frisian
Galician
Georgian
Gujarati
Haitian
Hausa
Hawaiian
Hebrew
Hmong
Hungarian
Icelandic
Igbo
Javanese
Kannada
Kazakh
Khmer
Kurdish
Kyrgyz
Latin
Latvian
Lithuanian
Luxembou..
Macedonian
Malagasy
Malay
Malayalam
Maltese
Maori
Marathi
Mongolian
Burmese
Nepali
Norwegian
Pashto
Persian
Punjabi
Serbian
Sesotho
Sinhala
Slovak
Slovenian
Somali
Samoan
Scots Gaelic
Shona
Sindhi
Sundanese
Swahili
Tajik
Tamil
Telugu
Thai
Ukrainian
Urdu
Uzbek
Vietnamese
Welsh
Xhosa
Yiddish
Yoruba
Zulu
Kinyarwanda
Tatar
Oriya
Turkmen
Uyghur