  • Portable Digital small Blood sample Glucose Meter

    Portable Digital small Blood sample Glucose Meter

    Item No. DM5279 Detection method electrochemical biosensing Test sample Fingertip capillary whole blood and venous whole blood Sample size 0.8μL Detection time 5s Scope of Test 10 – 600mg/dL HCT 15% ~ 70% Operation requirement 9℃ ~ 42℃(10% RH ~ 80% RH) Storage requirement 2-32℃ Average days calculation 7,14,21,28,60,90days Battery life ≥1000times Memory capacity 500sets Measurement Unit mg/dL Power supply 2 batteries Sleep mode below 2.5V Auto pow...
  • Chlamydia Rapid Test Kit simple operation test kit

    Chlamydia Rapid Test Kit simple operation test kit

    Sensitivity The Chlamydia Rapid Test Device has been evaluated with Chlamydia infected cells and specimens obtained from patients of STD clinics. The Chlamydia Rapid Test Device can detect 107 org/ml. Specificity The Chlamydia Rapid Test Device uses an antibody that is highly specific for Chlamydia antigen in specimens. The results show the Chlamydia Rapid Test Device has a high specificity relative to Other Test For Female Cervical Swab Specimens: Method Other Test Total             ...
  • Instant Urine Drug Test MET TEST KIT, Multi-Drug Test, Dip card, Panel

    Instant Urine Drug Test MET TEST KIT, Multi-Drug Test, Dip card, Panel

    Accuracy A side-by-side comparison was conducted using the MET One Step Methamphetamine Test and a leading commercially available MET rapid test. Testing was performed on 234 clinical specimens. Ten percent of the specimens employed were either at -25% or +25% level of the cut-off concentration of 1,000 ng/mL Methamphetamine. Presumptive positive results were confirmed by GC/MS. The following results were tabulated: Method Other MET Rapid Test Total Results MET One Step Test Device...
  • High Quality KET Drug Test Dip Card, Panel

    High Quality KET Drug Test Dip Card, Panel

    Accuracy A comparison was conducted using the KET One Step Ketamine Test and GC/MS at 1,000 ng/mL cut-off. The following results were tabulated: Method GC/MS Total Results KET One Step Test Results Positive Negative Positive 10 8 18 Negative 0 205 205 Total Results 10 213 223 % Agreement 100% 96.2% 96.4% Analytical Sensitivity A drug-free urine pool was spiked with Ketamine at the following concentrations: 0 ng/mL, 500ng/mL, 750 ...
  • Instant Urine Drug Test Kit K2 – CE approved

    Instant Urine Drug Test Kit K2 – CE approved

    A. Sensitivity One Step Synthetic Cannabis (K2) Test has set the screen cut-off for positive specimens at 25 ng/mL for JWH-018 Pentanoic Acid and JWH-073 Butanoic Acid as the calibrators. The test device has been proved to detect above the cut-off level of the target drugs in urine at 5 minutes. B.Specificity and cross reactivity To test the specificity of the test, the test device was used to test Synthetic Cannabis (K2), its metabolites and other components of the same class that are likely...
  • High Quality Medical Device COC Rapid TEST for Drugs

    High Quality Medical Device COC Rapid TEST for Drugs

    A. Sensitivity One Step Cocaine Test has set the screen cut-off for positive specimens at 300 ng/mL for benzoylecgonine as a calibrator. The test device has been proved to detect above 300 ng/mL of Cocaine in urine at 5 minutes. B. Specificity and cross reactivity To test the specificity of the test, the test device was used to test Cocaine, its metabolites and other components of the same class that are likely to be present in urine, All the components were added to drug-free normal human ur...
  • High accuracy Infectious Disease Typhoid Test kit

    High accuracy Infectious Disease Typhoid Test kit

    Clinical Performance For IgM Test A total of 334 samples from susceptible subjects were tested by the Typhoid Antibody Rapid Test and by a commercial S. typhi IgM EIA. Comparison for all subjects is showed in the following table. Method IgM EIA Total Results  Typhoid Antibody Rapid Test Results Positive Negative Positive 31 2 33 Negative 3 298 301 Total Results 34 300 334 Relative Sensitivity:91.2% (76.3% – 98.1%)* Relative Specificity: 99.3...
  • Test Diagnostic Medical Device CE marked Syphilis Test kit

    Test Diagnostic Medical Device CE marked Syphilis Test kit

    POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T). *NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of TP antibodies present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive. NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line reg...
  • CE approved wholesale Medical Device Strep A Test kit

    CE approved wholesale Medical Device Strep A Test kit

    Accuracy Table: Strep A AntigenRapid Test vs. PCR Test Method Culture Total Results Strep A Antigen Rapid Test Results Positive Negative Positive 102 7 109 Negative 6 377 383 Total Results 108 384 492 Relative Sensitivity: 94.4% (88.3%-97.9%)* Relative Specificity: 98.2% (96.3%-99.3%)* Accuracy: 97.4% (95.5%-98.6%)* * 95% Confidence Intervals INTENDED USE The Strep A Antigen Rapid Test is a rapid chromatographic immunoassay for the qualita...
  • One step High accuracy CE approved Malaria Pf/Pan Test kit

    One step High accuracy CE approved Malaria Pf/Pan Test kit

    Sensitivity The Malaria Pf/ Pan Rapid Test Device (Whole Blood) has been tested with thin or thick microscopy on clinical samples. The results show that the sensitivity of the Malaria P.f/ Pan Rapid Test Device (Whole Blood) is >99.9% relative to microscopy. For Pan: Relative Sensitivity: >99.9% (103/103) (96.5%~100.0%)* For P.f: Relative Sensitivity: >99.9% (53/53) (93.3%~100.0%)* Specificity The Malaria Pf/ Pan Rapid Test Device (Whole Blood) uses highly specific antibodies for M...
  • One step high accuracy Malaria P.f./P.v. Test kit

    One step high accuracy Malaria P.f./P.v. Test kit

    Sensitivity The Malaria P.f./ P.v. Rapid Test Device (Whole Blood) has been tested with microscopy on clinical samples. The results show that the sensitivity of the Malaria P.f./ P.v. Rapid Test Device (Whole Blood) is >98% when compared to results obtained with microscopy. Specificity The Malaria P.f./ P.v. Rapid Test Device (Whole Blood) uses antibodies that are highly specific to Malaria P.f.-specific and P.vivax LDH antigens in whole blood. The results show that the specificity of the ...
  • Medical use professional Typhoid Test kit, one step rapid test cassette

    Medical use professional Typhoid Test kit, one step rapid test cassette

    Clinical Sensitivity, Specificity and Accuracy The Influenza A+B Antigen Rapid Test has been tested compared with RT-PCR. 539 nasopharyngeal swabs and oropharyngeal swabs were evaluated with the Influenza A+B Rapid Test. Substances Concentration Substances Concentration Nasal Spray 15% v/v Hemoglobin 10% v/v Mucin 0.5 % w/v Mupirocin 10 mg/mL Nasal Drops 15% v/v Mouthwash / Chloraseptic 1.5 mg/mL Levofloxacin 40 ug/mL  Oseltamivir 2ug/mL...